Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.662
Filtrar
1.
J Bacteriol ; 206(4): e0004224, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38563759

RESUMO

In Salmonella enterica, the absence of the RidA deaminase results in the accumulation of the reactive enamine 2-aminoacrylate (2AA). The resulting 2AA stress impacts metabolism and prevents growth in some conditions by inactivating a specific target pyridoxal 5'-phosphate (PLP)-dependent enzyme(s). The detrimental effects of 2AA stress can be overcome by changing the sensitivity of a critical target enzyme or modifying flux in one or more nodes in the metabolic network. The catabolic L-alanine racemase DadX is a target of 2AA, which explains the inability of an alr ridA strain to use L-alanine as the sole nitrogen source. Spontaneous mutations that suppressed the growth defect of the alr ridA strain were identified as lesions in folE, which encodes GTP cyclohydrolase and catalyzes the first step of tetrahydrofolate (THF) synthesis. The data here show that THF limitation resulting from a folE lesion, or inhibition of dihydrofolate reductase (FolA) by trimethoprim, decreases the 2AA generated from endogenous serine. The data are consistent with an increased level of threonine, resulting from low folate levels, decreasing 2AA stress.IMPORTANCERidA is an enamine deaminase that has been characterized as preventing the 2-aminoacrylate (2AA) stress. In the absence of RidA, 2AA accumulates and damages various cellular enzymes. Much of the work describing the 2AA stress system has depended on the exogenous addition of serine to increase the production of the enamine stressor. The work herein focuses on understanding the effect of 2AA stress generated from endogenous serine pools. As such, this work describes the consequences of a subtle level of stress that nonetheless compromises growth in at least two conditions. Describing mechanisms that alter the physiological consequences of 2AA stress increases our understanding of endogenous metabolic stress and how the robustness of the metabolic network allows perturbations to be modulated.


Assuntos
Salmonella enterica , Scrapie , Ovinos , Animais , Salmonella enterica/genética , Acrilatos/metabolismo , Proteínas de Bactérias/genética , Fosfato de Piridoxal/metabolismo , Tetra-Hidrofolatos/metabolismo , Serina/metabolismo
2.
Int J Mol Sci ; 25(7)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38612383

RESUMO

Polyacrylic acid (PAA), an organic chemical, has been used as an intermediate in the manufacture of pharmaceuticals and cosmetics. It has been suggested recently that PAA has a high pulmonary inflammatory and fibrotic potential. Although endoplasmic reticulum stress is induced by various external and intracellular stimuli, there have been no reports examining the relationship between PAA-induced lung injury and endoplasmic reticulum stress. F344 rats were intratracheally instilled with dispersed PAA (molecular weight: 269,000) at low (0.5 mg/mL) and high (2.5 mg/mL) doses, and they were sacrificed at 3 days, 1 week, 1 month, 3 months and 6 months after exposure. PAA caused extensive inflammation and fibrotic changes in the lungs' histopathology over a month following instillation. Compared to the control group, the mRNA levels of endoplasmic reticulum stress markers Bip and Chop in BALF were significantly increased in the exposure group. In fluorescent immunostaining, both Bip and Chop exhibited co-localization with macrophages. Intratracheal instillation of PAA induced neutrophil inflammation and fibrosis in the rat lung, suggesting that PAA with molecular weight 269,000 may lead to pulmonary disorder. Furthermore, the presence of endoplasmic reticulum stress in macrophages was suggested to be involved in PAA-induced lung injury.


Assuntos
Acrilatos , Lesão Pulmonar , Polímeros , Ratos , Animais , Ratos Endogâmicos F344 , Estresse do Retículo Endoplasmático , Inflamação , Pulmão
3.
Niger J Clin Pract ; 27(3): 304-309, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38528349

RESUMO

BACKGROUND AND AIM: Gastroesophageal reflux disease causes gastric acid to enter the oral cavity, leading to mucosal changes and deterioration of dental hard tissues and materials. The purpose of this in vitro study was to evaluate the impact of gastric juice on the surface roughness of two types of acrylics used in provisional restorations. MATERIALS AND METHODS: Acrytemp ® and Temdent acrylic resin discs (10 × 2 mm) totaling 80 were manufactured and divided into eight groups (n = 10). Groups were prepared as follows: Group 1 (Temdent + Universal Polish) (control), Group 2 (Temdent + Universal Polish + Biscover LV), Group 3 (Temdent + Universal Polish + Resin Glaze), Group 4 (Temdent + Universal Polish + Fortify Plus), Group 5 (Acrytemp + Universal Polish) (control), Group 6 (Acrytemp + Universal Polish + Biscover LV), Group 7 (Acrytemp + Universal Polish + Resin Glaze), and Group 8 (Acrytemp + Universal Polish + Fortify Plus). The resin discs were immersed in distilled water for 24 h and in gastric juice (pH = 2) for additional 24 h. The initial and final roughness values of samples were measured and analyzed with non-parametric statistics including Mann-Whitney U-test for pairwise comparison, Kruskall Wallis test for comparing more than two groups, and Wilcoxon signed rank test for within-group comparison (P < 0.05). RESULTS: Surface roughness did not differ significantly between control groups. It notably increased for all samples with surface sealants, both initially and after gastric juice immersion (P < 0.05). CONCLUSION: Surface sealants noticeably increased the roughness of two types of acrylic resins. After immersing in gastric juice, Group 4 (Temdent + Universal Polish + Fortify Plus) showed the highest roughness, while the untreated control groups remained the smoothest.


Assuntos
Acrilatos , Resinas Acrílicas , Resinas Compostas , Cimentos de Resina , Humanos , Propriedades de Superfície , Teste de Materiais , Suco Gástrico , Materiais Dentários
4.
J Adhes Dent ; 26(1): 87-92, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38465403

RESUMO

PURPOSE: This paper describes previously unknown details about the discovery of resin adhesion to acid-etched human enamel. MATERIALS AND METHODS: A literature review was performed through manual assessments. Primary sources revealing the discovery of resin curing on etched enamel were analyzed considering the research objectives and methodological procedure during that era, including the type of teeth used, preparatory measures, acid-etching process, type of resin and its application, and follow-up observations. Additionally, the political and economic contexts were examined. RESULTS: In 1949, acid etching was found to promote adhesion with acrylic resin, a finding described again in 1955. The 1949 studies utilized nitric acid for enamel etching and the acrylate resin Paladon from the Kulzer company (Germany). Conversely, the 1955 investigations employed phosphoric acid and an unnamed acrylate, likely a self-curing resin supported by Kulzer in the late 1930s. Disparities in the 1949 and 1955 findings can be ascribed to varying objectives and test conditions amidst a turbulent political backdrop, significantly impacting the Kulzer company. CONCLUSION: The discovery of resin adhesion to acid-etched enamel, approaching its 75th anniversary in 2024, is a landmark in 20th-century adhesive dentistry. Paladon represents a pioneering compound, exemplifying the influence of political, ideological, and economic factors on scientific advancements during that period.


Assuntos
Colagem Dentária , Humanos , Condicionamento Ácido do Dente/métodos , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Esmalte Dentário , Ácidos Fosfóricos , Acrilatos , Cimentos de Resina , Teste de Materiais
5.
Int J Biol Macromol ; 265(Pt 2): 131115, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38522691

RESUMO

A cellulose-reinforced eutectogel was constructed by deep eutectic solvent (DES) and cotton linter cellulose. Cellulose was dispersed in the ternary DES consisting of acrylic acid, choline chloride and AlCl3·6H2O. The photoinitiator was then introduced into the system to in situ polymerize acrylic acid monomer to form transparent and ionic conductive eutectogels while keeping all the DES. The crosslinks formed by Al3+ induced ionic bonds and reversible links formed by hydrogen bonds give the eutectogels high stretchability (3200 ± 200 % tensile strain), self-adhesive (52.1 kPa to glass), self-healing and good mechanical strength (670 kPa). The eutectogels were assembled into sensors and epidermal patch electrodes that demonstrated high quality human motion sensing and physiological signal detection (electrocardiogram and electromyography). This work provides a facile way to design flexible electronics for sensing.


Assuntos
Acrilatos , Celulose , Humanos , Colina , Condutividade Elétrica
6.
Acta Derm Venereol ; 104: adv19676, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38551376

RESUMO

Allergic contact dermatitis is reported among individuals using continuous glucose monitoring systems and insulin pumps. The aim of this study was to describe contact allergy patterns for allergens in the Swedish baseline series and medical device-related allergens among users. Contact allergy to baseline series allergens and isobornyl acrylate was compared between diabetes patients and dermatitis patients patch-tested at the Department of Occupational and Environmental Dermatology during 2017 to 2020. Fifty- four diabetes patients and 2,567 dermatitis patients were included. The prevalence of contact allergy to fragrance mix II and sesquiterpene lactone mix was significantly higher in diabetes patients compared with dermatitis patients. Of the diabetes patients 13.0% and of the dermatitis patients 0.5% tested positive to sesquiterpene lactone mix (p < 0.001). Of the diabetes patients 7.4% and of the dermatitis patients 2.3% tested positive to fragrance mix II (p = 0.041). Of the diabetes patients 70.4% tested positive to medical device-related allergens. Of the diabetes patients 63.0% and of the dermatitis patients 0.2% were allergic to isobornyl acrylate (p < 0.001). In conclusion, not only medical device-related contact allergies, but also contact allergy to baseline series allergens (fragrance mix II and sesquiterpene lactone mix), is overrepresented in diabetes patients who use medical devices.


Assuntos
Acrilatos , Canfanos , Dermatite Alérgica de Contato , Diabetes Mellitus , Sesquiterpenos , Humanos , Alérgenos/efeitos adversos , Estudos Retrospectivos , Suécia/epidemiologia , Automonitorização da Glicemia , Glicemia , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/induzido quimicamente , Testes do Emplastro , Lactonas
7.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(1): 87-94, 2024 Jan 20.
Artigo em Chinês | MEDLINE | ID: mdl-38322512

RESUMO

Objective: To construct microscale rectangular hydrogel grooves and to investigate the morphology and alignment of human umbilical vein endothelial cells (HUVECs) under spatial constraints. Vascular endothelial cell morphology and alignment are important factors in vascular development and the maintenance of homeostasis. Methods: A 4-arm polyethylene glycol-acrylate (PEG-acrylate) hydrogel was used to fabricate rectangular microgrooves of the widths of 60 µm, 100 µm, and 140 µm. The sizes and the fibronectin (FN) adhesion of these hydrogel microgrooves were measured. HUVECs were seeded onto the FN-coated microgrooves, while the flat surface without micropatterns was used as the control. After 48 hours of incubation, the morphology and orientation of the cells were examined. The cytoskeleton was labelled with phalloidine and the orientation of the cytoskeleton in the hydrogel microgrooves was observed by laser confocal microscopy. Results: The hydrogel microgrooves constructed exhibited uniform and well-defined morphology, a complete structure, and clear edges, with the width deviation being less than 3.5%. The depth differences between the hydrogel microgrooves of different widths were small and the FN adhesion is uniform, providing a micro-patterned growth interface for cells. In the control group, the cells were arranged haphazardly in random orientations and the cell orientation angle was (46.9±1.8)°. In contrast, the cell orientation angle in the hydrogel microgrooves was significantly reduced (P<0.001). However, the cell orientation angles increased with the increase in hydrogel microgroove width. For the 60 µm, 100 µm, and 140 µm hydrogel microgrooves, the cell orientation angles were (16.4±2.8)°, (24.5±3.2)°, and (30.3±3.5)°, respectively. Compared to that of the control group (35.7%), the number of cells with orientation angles <30° increased significantly in the hydrogel microgrooves of different widths (P<0.001). However, as the width of the hydrogel microgrooves increased, the number of cells with orientation angles <30° gradually decreased (79.9%, 62.3%, 54.7%, respectively), while the number of cells with orientation angles between 60°-90° increased (P<0.001). The cell bodies in the microgrooves were smaller and more rounded in shape. The cells were aligned along the direction of the microgrooves and corresponding changes occurred in the arrangement of the cell cytoskeleton. In the control group, cytoskeletal filaments were aligned in random directions, presenting an orientation angle of (45.5±3.7)°. Cytoskeletal filaments were distributed evenly within various orientation angles. However, in the 60 µm, 100 µm, and 140 µm hydrogel microgrooves, the orientation angles of the cytoskeletal filaments were significantly decreased, measuring (14.4±3.1)°, (24.7±3.5)°, and (31.9±3.3)°, respectively. The number of cytoskeletal filaments with orientation angles <30° significantly increased in hydrogel microgrooves of different widths (P<0.001). However, as the width of the hydrogel microgrooves increased, the number of cytoskeletal filaments with orientation angles <30° gradually decreased, while the number of cytoskeletal filaments with orientation angles between 60°-90° gradually increased (P<0.001). Conclusion: Hydrogel microgrooves can regulate the morphology and orientation of HUVECs and mimic to a certain extent the in vivo microenvironment of vascular endothelial cells, providing an experimental model that bears better resemblance to human physiology for the study of the unique physiological functions of vascular endothelial cells. Nonetheless, the molecular mechanism of spatial constraints on the morphology and the assembly of vascular endothelial cell needs to be further investigated.


Assuntos
Acrilatos , Hidrogéis , Humanos , Células Endoteliais da Veia Umbilical Humana , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Adesão Celular
8.
Biomacromolecules ; 25(3): 1637-1648, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38381566

RESUMO

Cellulose nanocrystals (CNCs) are bio-based, rod-like, high-aspect-ratio nanoparticles with high stiffness and strength and are widely used as a reinforcing nanofiller in polymer nanocomposites. However, due to hydrogen-bond formation between the large number of hydroxyl groups on their surface, CNCs are prone to aggregate, especially in nonpolar polymer matrices. One possibility to overcome this problem is to graft polymers from the CNCs' surfaces and to process the resulting "hairy nanoparticles" (HNPs) into one-component nanocomposites (OCNs) in which the polymer matrix and CNC filler are covalently connected. Here, we report OCNs based on HNPs that were synthesized by grafting gradient diblock copolymers onto CNCs via surface-initiated atom transfer radical polymerization. The inner block (toward the CNCs) is composed of poly(methyl acrylate) (PMA), and the outer block comprises a gradient copolymer rich in poly(methyl methacrylate) (PMMA). The OCNs based on such HNPs microphase separate into a rubbery poly(methyl acrylate) phase that dissipates mechanical energy and imparts toughness, a glassy PMMA phase that provides strength and stiffness, and well-dispersed CNCs that further reinforce the materials. This design afforded OCNs that display a considerably higher stiffness and strength than reference diblock copolymers without the CNCs. At the same time, the extensibility remains high and the toughness is increased up to 5-fold relative to the reference materials.


Assuntos
Acrilatos , Nanocompostos , Nanopartículas , Celulose/química , Polimetil Metacrilato , Polímeros/química , Nanopartículas/química , Nanocompostos/química
9.
Int J Biol Macromol ; 262(Pt 2): 129946, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38340936

RESUMO

Organic dye pollution from textiles and other industries presents a substantial risk to people and aquatic life. The use of photocatalysis to decolorize water using the strength of UV light is one of the most important remediation techniques. In the present study, a novel nanocomposites hydrogel including carboxymethyl cellulose (CMC), acrylic acid (AAc), Zinc oxide (ZnO), and silver (Ag) nanoparticles was produced using an eco-friendly γ-irradiation technique for photocatalytic decolorization applications. ZnO and Ag nanoparticles were distributed in the CMC/AAc hydrogel matrix without significant aggregation. SEM, XRD, EDX, TEM, and FTIR analyses were used to assess the physicochemical characteristics of the nanocomposite samples. Carboxymethyl cellulose/acrylic acid/Zinc oxide doped silver (CMC/PAAc/ZnO@Ag) nanocomposite hydrogels were developed and utilized in the photocatalytic decolorization of the lerui acid brilliant blue dye (LABB) when exposed to ultraviolet (UV) radiation. UV- Vis spectrophotometry was utilized to analyze the optical properties of the produced nanostructure. Regarding the decolorization of the LABB, the impacts of operational variables were investigated. The optimum conditions for decolorization (93 %) were an initial concentration of 50 mg/L, pH = 4, catalyst dosage of 50 g/L, and exposure time of 90 min. The results illustrated that the LABB acidic dye from wastewater was remarkably decolored.


Assuntos
Acrilatos , Benzenossulfonatos , Nanopartículas Metálicas , Nanocompostos , Óxido de Zinco , Humanos , Óxido de Zinco/química , Hidrogéis/química , Prata/química , Carboximetilcelulose Sódica/química , Nanopartículas Metálicas/química , Corantes/química , Nanocompostos/química
10.
Int J Biol Macromol ; 262(Pt 2): 130042, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38342266

RESUMO

This paper introduces the synthesis of an environmentally friendly emulsion that can be used as a soil anti-water erosion material. SSPS-g-P(BA-co-MMA-co-AA) emulsions were prepared using free radical copolymerization with soybean soluble polysaccharide (SSPS), acrylic acid (AA), butyl acrylate (BA), and methyl methacrylate (MMA). The structure, thermal stability, and morphology were characterized using FT-IR,TG,SEM, and particle diameter analysis. The resistance to water erosion, compressive strength and water retention of emulsion-treated loess/laterite was studied and germination tests were conducted. The results demonstrated that the duration of washout resistance of loess with 0.50 wt% emulsion exceeded 99 h, and the water erosion rate was 56.0 % after 72 h, while the water erosion rate of pure loess is 100.0 % after 4 min;the duration of washout resistance of laterite with 0.50 wt% emulsion exceeded 2 h, which was 8 times longer than pure laterite;The compressive strengths of 0.5 wt% emulsion-treated loess/laterite were 3.5 Mpa and 5.8 MPa, respectively, which were 7 and 9 times higher than that of pure soil. The plant seeds germinated normally half a month after planting. These findings suggest that emulsions can be used to control soil erosion without affecting the germination of plant seeds.


Assuntos
Acrilatos , Soja , Erosão do Solo , Emulsões/química , Espectroscopia de Infravermelho com Transformada de Fourier , Solo , Polissacarídeos/química , Água
11.
Acta Biomater ; 177: 165-177, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38354873

RESUMO

Four-dimensional (4D) printing unlocks new potentials for personalized biomedical implantation, but still with hurdles of lacking suitable materials. Herein, we demonstrate a bioresorbable shape memory elastomer (SME) with high elasticity at both below and above its phase transition temperature (Ttrans). This SME can be digital light 3D printed by co-polymerizing glycerol dodecanoate acrylate prepolymer (pre-PGDA) with acrylic acid monomer to form crosslinked Poly(glycerol dodecanoate acrylate) (PGDA)-Polyacrylic acid (PAA), or PGDA-PAA network. The printed complex, free-standing 3D structures with high-resolution features exhibit shape programming properties at a physiological temperature. By tuning the pre-PGDA weight ratios between 55 wt% and 70 wt%, Ttrans varies between 39.2 and 47.2 ℃ while Young's moduli (E) range 40-170 MPa below Ttrans with fractural strain (εf) of 170 %-200 %. Above Ttrans, E drops to 1-1.82 MPa which is close to those of soft tissue. Strikingly, εf of 130-180 % is still maintained. In vitro biocompatibility test on the material shows > 90 % cell proliferation and great cell attachment. In vivo vascular grafting trials underline the geometrical and mechanical adaptability of these 4D printed constructs in regenerating the aorta tissue. Biodegradation of the implants shows the possibility of their full replacement by natural tissue over time. To highlight its potential for personalized medicine, a patient-specific left atrial appendage (LAA) occluder was printed and implanted endovascularly into an in vitro heart model. STATEMENT OF SIGNIFICANCE: 4D printed shape-memory elastomer (SME) implants particularly designed and manufactured for a patient are greatly sought-after in minimally invasive surgery (MIS). Traditional shape-memory polymers used in these implants often suffer from issues like unsuitable transition temperatures, poor biocompatibility, limited 3D design complexity, and low toughness, making them unsuitable for MIS. Our new SME, with an adjustable transition temperature and enhanced toughness, is both biocompatible and naturally degradable, particularly in cardiovascular contexts. This allows implants, like biomedical scaffolds, to be programmed at room temperature and then adapt to the body's physiological conditions post-implantation. Our studies, including in vivo vascular grafts and in vitro device implantation, highlight the SME's effectiveness in aortic tissue regeneration and its promising applications in MIS.


Assuntos
Elastômeros , Tecidos Suporte , Humanos , Elastômeros/química , Tecidos Suporte/química , Glicerol , Implantes Absorvíveis , Lauratos , Impressão Tridimensional , Acrilatos
12.
J Chromatogr A ; 1717: 464708, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38330846

RESUMO

The Poly acrylic acid/MIL-88(Fe)-NH2 composite material, carefully prepared, is employed as a sorbent for the stir bar. The best formula of the composite was selected by investigation of two parameters including the cross-linker of PAA and MIL-88(Fe)-NH2 content. The prepared stir bar was used for extraction of 2-pentanone, 2-heptanone, ethyl propionate, para-xylene, 1,2,4-trimethylbenzene, o-cresol, m-cresol in urine samples as breast cancer biomarkers with gas chromatography-flame ionization detector. The prepared Poly acrylic acid / MIL-88(Fe)-NH2 as sorbent for the stir bar demonstrate good repeatability of one bar (relative standard deviation (RSD%) < 4.61 %) and satisfactory reproducibility between two bars (RSD% < 6.85 %). The central composite design method was applied for the optimization of extraction parameters. Under the optimum conditions, linear dynamic ranges for compounds were in the acceptable range with correlation coefficients higher than 0.99. Detection limits of them were less than 1.71 µg L-1.


Assuntos
Acrilatos , Biomarcadores Tumorais , Neoplasias da Mama , Humanos , Feminino , Reprodutibilidade dos Testes , Hidrogéis , Limite de Detecção
13.
Molecules ; 29(4)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38398568

RESUMO

Ionizing radiation (IR)-induced hematopoietic injury has become a global concern in the past decade. The underlying cause of this condition is a compromised hematopoietic reserve, and this kind of hematopoietic injury could result in infection or bleeding, in addition to lethal mishaps. Therefore, developing an effective treatment for this condition is imperative. Fluacrypyrim (FAPM) is a recognized effective inhibitor of STAT3, which exhibits anti-inflammation and anti-tumor effects in hematopoietic disorders. In this context, the present study aimed to determine whether FAPM could serve as a curative agent in hematopoietic-acute radiation syndrome (H-ARS) after total body irradiation (TBI). The results revealed that the peritoneally injection of FAPM could effectively promote mice survival after lethal dose irradiation. In addition, promising recovery of peripheral blood, bone marrow (BM) cell counts, hematopoietic stem cell (HSC) cellularity, BM colony-forming ability, and HSC reconstituting ability upon FAPM treatment after sublethal dose irradiation was noted. Furthermore, FAPM could reduce IR-induced apoptosis in hematopoietic stem and progenitor cells (HSPCs) both in vitro and in vivo. Specifically, FAPM could downregulate the expressions of p53-PUMA pathway target genes, such as Puma, Bax, and Noxa. These results suggested that FAPM played a protective role in IR-induced hematopoietic damage and that the possible underlying mechanism was the modulation of apoptotic activities in HSCs.


Assuntos
Proteínas Reguladoras de Apoptose , Células-Tronco Hematopoéticas , Pirimidinas , Camundongos , Animais , Proteínas Reguladoras de Apoptose/metabolismo , Acrilatos/farmacologia , Apoptose , Irradiação Corporal Total , Camundongos Endogâmicos C57BL
14.
Contact Dermatitis ; 90(5): 495-500, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38316128

RESUMO

BACKGROUND: Allergic contact dermatitis (ACD) has been reported as an adverse effect from the use of several glucose sensors and insulin pumps from different manufacturers. Isobornyl acrylate (IBOA) has been identified as a major culprit sensitizer, but also other acrylates and (modified) colophonium have been reported as causes of ACD. OBJECTIVES: To report the two first cases diagnosed with ACD caused by the Dexcom G7 (DG7) glucose sensor. PATIENTS AND METHODS: Two children with suspected ACD from DG7 were patch tested with our medical device series with an addition of selected test preparations including two variants of modified colophonium - methyl hydrogenated rosinate (MHR) and glyceryl hydrogenated rosinate (GHR). Both patients were also tested with acetone extracts made from different parts of the DG7 sensor. The extracts were analysed by gas chromatography-mass spectrometry (GC-MS). RESULTS: Both patients tested positive to IBOA, hydroabietyl alcohol and GHR. In addition, patient 1 had a positive reaction to MHR and patient 2 had a positive reaction to colophonium. The GC-MS analyses showed the presence of IBOA and colophonium-related substances in the DG7 extracts. CONCLUSIONS: Both patients were diagnosed with contact allergy to well-known medical device-related sensitizers. The presence of IBOA and (modified) colophonium in a newly introduced (on the Swedish market in 2023) glucose sensor is remarkable and indicates an inadequate toxicological assessment of the materials used in the sensor.


Assuntos
Alérgenos , Canfanos , Dermatite Alérgica de Contato , Criança , Humanos , Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Automonitorização da Glicemia/efeitos adversos , Adesivos/efeitos adversos , Acrilatos/efeitos adversos , Glucose , Testes do Emplastro/efeitos adversos
15.
Contact Dermatitis ; 90(5): 501-506, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38332444

RESUMO

BACKGROUND: Many people live with ostomies after life-saving surgery. Ostomy patients often suffer from peristomal dermatitis. Allergic contact dermatitis (ACD) has been reported, mostly due to contact allergy (CA) to topical agents. OBJECTIVES: We present three patients with therapy resistant peristomal dermatitis, suggesting ACD caused by different stoma products. METHODS: Patch testing was performed with baseline series, additional series, and selected allergens. They were also tested with their own ostomy products as is and separate extracts of the products. Extracts were analysed using Gas Chromatography-Mass Spectrometry (GC-MS). RESULTS: In all three patients we diagnosed CA to 1,6-hexanediol diacrylate (HDDA), +++ in case (C) 1 and 3, ++ in C 2. HDDA was detected in C 2's ostomy pouch adhesive and in C 1's and 3's flange extenders used to improve the adhesion of the ostomy pouches. CONCLUSION: Therapy resistant peristomal dermatitis should always be suspected of ACD and patch testing, especially with the patient's own products, should be performed.


Assuntos
Dermatite Alérgica de Contato , Estomia , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Estomia/efeitos adversos , Acrilatos/efeitos adversos , Alérgenos/efeitos adversos , Testes do Emplastro/métodos
17.
J Prosthet Dent ; 131(4): 708.e1-708.e8, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38383280

RESUMO

STATEMENT OF PROBLEM: Removable dental prostheses require periodic relining with the loss of intaglio surface fit because of mucosal shape changes over time. Therefore, a new material with high adaptability to tissue changes over time would be beneficial. PURPOSE: This study focused on a shape-memory gel (SMG) that softens when heated, retains its shape when cooled, and returns to its original shape when reheated. The purpose was to optimize SMG for intraoral use by controlling the ratio of 2 acrylate monomers and to evaluate the changes in the shape memory and physical properties of SMG with temperature and to evaluate biocompatibility. MATERIAL AND METHODS: SMG specimens were synthesized using the following mixing ratios of 2 monomers, docosyl acrylate (DA) and stearyl acrylate (SA): 0:100, 25:75, 50:50, 75:25, and 100:0. SMG specimens were photopolymerized using a fluorescent light-polymerizing unit. To evaluate shape memory as a function of temperature, permanent deformation was measured based on the standardized compression set test for thermoplastic rubber. For evaluation of the physical properties and cytotoxicity, a 3-dimensionally printed denture base material was used as the control material. All assessments were compared between the groups by using 1-way analysis of variance followed by the Tukey-Kramer multiple comparison test (α=.05). RESULTS: SMGs with a higher amount of DA maintained their compressed shape at room and intraoral temperatures. However, the SMG matrices softened and recovered their original shapes above 60 °C. SMGs showed Shore A hardness equivalent to that of the denture-base polymer material at intraoral temperatures because of the high phase-transition temperature. The low water solubility of SMGs supported the biocompatibility test results. CONCLUSIONS: SMG, in which the phase-transition temperature was controlled by mixing acrylate monomers with different melting points, exhibited shape memory in the intraoral environment. The results indicate the feasibility of applying SMG for the fabrication of removable dental prostheses because of its high adaptability to tissue changes over time and biocompatibility.


Assuntos
Acrilatos , Prótese Dentária , Temperatura , Temperatura de Transição , Teste de Materiais
18.
Contact Dermatitis ; 90(5): 507-513, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38351475

RESUMO

BACKGROUND: A global epidemic of allergic contact dermatitis to (meth)acrylates has been described in relation to the widespread use of manicure products. OBJECTIVES: To evaluate the frequency of sensitization to 2-hydroxyethyl methacrylate (2-HEMA) among consecutively patch tested patients with eczema in Spain; the percentage of current relevance; the MOAHLFA index; and, the potential sources of exposure to (meth)acrylates. METHODS: From January 2019 to December 2022, 2-HEMA 2% pet. was prospectively patch tested in 24 REIDAC (Spanish Allergic Contact Dermatitis Registry) centres. RESULTS: Six thousand one hundred thirty-four patients were consecutively patch tested with 2-HEMA 2% pet. 265/6134 (4.3%) were positive. Positive reactions of current relevance were identified to involve 184/265 (69%). The efficiency (number of patch tests needed to detect relevant positive patch test reactions) was 34 (6134/184). The variable 'occupational' was found to be significantly associated with a higher risk for relevant positive reactions to 2-HEMA (OR: 10.9; 95% CI: 8.1-14.9). CONCLUSION: (Meth)acrylate sensitization is a prevalent health issue in Spain. 2-HEMA 2% pet. has been identified to be a highly effective (meth)acrylate allergy marker in the GEIDAC baseline series. The responsible authorities should implement policies guaranteeing accurate labelling of industrial, medical, and consumer materials while ensuring the enforcement of said labelling through appropriate legal means.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Espanha/epidemiologia , Metacrilatos/efeitos adversos , Acrilatos , Testes do Emplastro
19.
Contact Dermatitis ; 90(3): 273-279, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38164086

RESUMO

BACKGROUND: The growing popularity of nail techniques based on acrylates has led to a higher frequency of sensitization in both nail technicians and users. OBJECTIVES: The study aimed to assess cases of allergic contact dermatitis (ACD) caused by acrylates in individuals with occupational or non-occupational exposure to nail techniques. METHODS: A preliminary study was conducted on 30 patients with ACD caused by acrylates in nail techniques, who were patch tested from September 2022 to March 2023 at the First Department of Dermatology and Venereology of Andreas Syggros Hospital, Athens, Greece. RESULTS: Thirty female patients with ACD to acrylates were documented (15 users and 15 nail technicians and users). The most common allergens were: 2-hydroxyethyl methacrylate (HEMA), 2-hydroxypropyl methacrylate (HPMA) and ethyleneglycol dimethacrylate (EGDMA), which tested positive in all 30 patients (100.0%). Twenty patients (66.7%) had been exposed to dental procedures involving acrylates, before the onset of ACD. Nail technicians exhibited extensive skin lesions, 40.0% experienced ACD within the first year of work and 13.3% during their professional practice. Three of them (20.0%) had to discontinue their work. CONCLUSION: Acrylates have been identified as potent allergens, necessitating the implementation of safety measures for the use of these chemicals in nail techniques.


Assuntos
Cosméticos , Dermatite Alérgica de Contato , Dermatite Ocupacional , Humanos , Feminino , Dermatite Alérgica de Contato/etiologia , Acrilatos/efeitos adversos , Projetos Piloto , Grécia , Testes do Emplastro/métodos , Estudos Retrospectivos , Metacrilatos/efeitos adversos , Alérgenos , Cosméticos/efeitos adversos , Dermatite Ocupacional/complicações
20.
Int J Biol Macromol ; 262(Pt 1): 129802, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38296149

RESUMO

Starch is a biomass polymer material with a high yield and comprehensive source. It is used as a raw material for preparing adhesives because of its highly active hydroxyl group. However, poor adhesion and water resistance hinder the application of starch-based adhesives (SBAs). Based on this, the starch was modified through graft copolymerization with itaconic acid as a cross-linking agent, methyl methacrylate and methyl acrylate as copolymers. Additionally, reed fibers were synergistically modified with polydopamine deposition to prepare an environmentally friendly SBA used in plywood production. Fourier transform infrared spectroscopy (FT-IR), nuclear magnetic resonance spectroscopy (1H NMR), X-ray diffraction (XRD), and thermogravimetric analysis (TG) demonstrate that copolymerization of methyl methacrylate and methyl acrylate with starch improves the shear strength, water resistance, and thermal stability of the SBA. Compared to unmodified starch, the modified SBA exhibits a 129 % increase in dry strength and achieves a wet strength of 1.36 MPa. Fukui function, Frontier orbit theory, and molecular dynamics simulation have shown that itaconic acid promotes the copolymerization of starch and acrylate monomers. The modified starch has fewer hydrogen bonds, less order, and a denser macromolecular network structure, which provides a reference for studying the molecular interaction mechanisms of SBAs.


Assuntos
Acrilatos , Simulação de Dinâmica Molecular , Amido , Succinatos , Amido/química , Adesivos/química , Espectroscopia de Infravermelho com Transformada de Fourier , Água/química , Metacrilatos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...